Grapevine Leaf Roll Closterovirus 5 (GLRaV-5)                             Home    Products    Testing Services   Supplies   Contact Us

Catalog #:  VS24
Source Antibody:
  Rabbit polyclonal antibody for both capture and detection.
Test Format:                                   

Reactivity:  Reaction of the ELISA is moderately strong.  Optical Density at 405nm is in a range of 0.800 - 1.800 depending on the virus titer in the samples tested.

Sensitivity:  Sensitivity of the ELISA is relative high.  The virus can be consistently detected in infected plant tissues diluted at 1:810 - 1:2430.

Specificity:  This test system has no cross reaction with healthy plant tissues tested. Background is very low on the negative control wells.

Products: 

Catalog Number

Description Test Wells Price $USD Ship Weight
(Estimated)
VS24-R1 ELISA Reagents

500

520

2 lb (1 kg)
VS24-R2 ELISA Reagents

1000

870

3 lb (1.5 kg)
VS24-R3 ELISA Reagents

5000

3200

6 lb (3 kg)
VS24-K1 ELISA Kit

500

720

2 lb (1 kg)
VS24-P1 Positive control 10 55 1 lb (0.5 kg)
VS24-N1 Negative control 20 40 1 lb (0.5 kg)

It is easy and convenient: To Place An Order 
To know more about the products:
  Product Items
To learn how to perform the test:
  Instructions for DAS ELISA
To be familiar with other components: Buffer Sets; Controls

Information About the Virus

Name: Grapevine Leaf Roll Closterovirus 5
Acronym:  GLRaV-5
Synonyms: 
Genus: 

Strains:      
Transmission: Transmitted by Pseudococcus longispinus, Planococcus ficus (GLRaV-3). Virus transmitted by grafting.

Geographical Distribution:  Probably distributed worldwide.
Diagnostically Susceptible Species and Symptoms: Vitis vinifera cvs Cabernet, Pinot Noir, Mission, Gamay - leafrolling and discoloration.

References:
Candresse, T. and Martelli, G.P. (1995). Arch. Virol., Suppl. 10: 461.